Bio Gas Generator
Harness renewable energy from organic waste with Igamogen biogas generator sets. Specially engineered to operate on biogas produced from agricultural waste, food processing, animal manure, and municipal sewage, these generators turn waste into valuable electricity and heat while reducing greenhouse gas emissions.
Available in a wide range of power outputs, our units are engineered to meet both prime and standby power requirements with ease.
Explore our wide range of Bio Gas Generator Sets:
| Parameter | Specification |
|---|---|
| Model | IGM12VCG-1000B5HC |
| Rated Power (kW) | 1000 kW |
| Rated Apparent Power (kVA) | 1250 kVA |
| Output Voltage (V) | 10,500 V |
| Frequency (Hz) | 50 Hz |
| Speed (RPM) | 1500 RPM |
| Power Factor (lagging) | 0.8 |
| Duty Rating | Prime / Standby |
| Power Rating @ 100% kWe | 1000 kW |
| Genset Prime Rating (kVA) | 1250 kVA |
| No. of Phases | 3-Phase |
| Current (A) | 69 A |
| Frequency & RPM | 50 Hz @ 1500 RPM |
| Governing Class | G2 (ISO 8528 Compliant – ±1% Frequency Control) |
| Parameter | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM12VCG-1000B5HC |
| Rated Engine Power (kW) | 1100 kW |
| No. of Cylinders | 12 – 16 |
| Cylinder Arrangement | V-Type |
| Stroke Type | 4-Stroke |
| Class of Insulation | H-Class |
| Bore × Stroke (mm) | 145 × 170 mm |
| Displacement | ~38 – 45 Litres |
| Cooling System | Water-cooled / Closed-loop with radiator |
| Parameter | Specification |
|---|---|
| Model | IGM12VCG-1000B5LC |
| Rated Output Power (kW) | 1000 kW |
| Rated Apparent Power (kVA) | 1250 kVA |
| Output Voltage (V) | 400 V |
| Frequency (Hz) | 50 Hz |
| Speed (RPM) | 1500 RPM |
| Power Factor (Lagging) | 0.8 |
| Duty | Prime / Standby |
| Power Rating @ 100% kWe | 1000 kW |
| Genset Prime Rating (kVA) | 1250 kVA |
| Number of Phases | 3-Phase |
| Current (A) | 1805 A |
| Frequency & RPM | 50 Hz @ 1500 RPM |
| Governing Class | G2 – ISO 8528 compliant |
| Parameter | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM12VCG-1000B5LC |
| Rated Engine Power (kW) | 1100 kW |
| No. of Cylinders | 12 – 16 |
| Cylinder Arrangement | V-Type |
| Stroke | 4-Stroke |
| Class of Insulation | H-Class |
| Bore × Stroke (mm) | 145 × 170 mm |
| Displacement (Ltr) | 38 – 45 Litres |
| Cooling System | Water-cooled / Closed loop / Radiator-based |
| Parameter | Specification |
|---|---|
| Model | IGM12VTDG-800B5HC |
| Rated Output Power (kW) | 800 kW |
| Rated Apparent Power (kVA) | 1000 kVA |
| Output Voltage (V) | 10,500 V |
| Frequency (Hz) | 50 Hz |
| Speed (RPM) | 1500 RPM |
| Power Factor (Lagging) | 0.8 |
| Duty | Prime / Standby |
| Power Rating @ 100% kWe | 800 kW |
| Genset Prime Rating (kVA) | 1000 kVA |
| Number of Phases | 3-Phase |
| Current (A) | 44 A |
| Frequency & RPM | 50 Hz @ 1500 RPM |
| Governing Class | G2 – ISO 8528 compliant |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM12VTDG-800B5HC |
| Rated Engine Power (kW) | 850 kW |
| Number of Cylinders | 12 |
| Cylinder Arrangement | V-Type |
| Stroke Type | 4-Stroke |
| Class of Insulation | H-Class |
| Bore × Stroke (mm) | 135 × 150 mm |
| Displacement | ~28 – 32 Litres |
| Cooling System | Water-cooled |
| Parameter | Specification |
|---|---|
| Model | IGM12VTDG-800B5LC |
| Rated Power Output (kW) | 800 kW |
| Rated Apparent Power (kVA) | 1000 kVA |
| Voltage (V) | 400 V |
| Frequency (Hz) | 50 Hz |
| Speed (RPM) | 1500 RPM |
| Duty | Prime / Standby |
| Power Rating @ 100% kWe | 800 kW |
| Power Factor (Lagging) | 0.8 |
| Number of Phases | 3-Phase |
| Current (A) | 1155 A |
| Governing Class | G2 (ISO 8528-5 Standard) |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM12VTDG-800B5LC |
| Rated Engine Power (kW) | 850 kW |
| Number of Cylinders | 12 |
| Cylinder Arrangement | V-Type |
| Stroke | 4-Stroke |
| Bore × Stroke (mm) | 135 × 150 mm |
| Displacement | 28 – 32 Litres |
| Cooling System | Water-cooled / Radiator-based |
| Class of Insulation | H-Class |
| Parameter | Specification |
|---|---|
| Model | IGM12VTDG-700B5HC |
| Voltage (V) | 10,500 V (Medium Voltage Output) |
| Frequency (Hz) | 50 Hz |
| Power Output (kW) | 700 kW |
| Power Output (kVA) | 875 kVA |
| Power Factor (Lagging) | 0.8 |
| Speed (RPM) | 1500 RPM |
| Genset Prime Rating (kVA) | 875 kVA (Prime Power) |
| Duty Rating | Prime / Standby |
| Power Rating @ 100% kWe | 700 kW |
| Number of Phases | 3-Phase |
| Output Voltage (V) | 10,500 V |
| Current (A) | 48 A |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Governing Class | G2 (±1% Frequency Variation) |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM12VTDG-700B5HC |
| Rated Engine Power (kW) | 750 kW |
| Number of Cylinders | 12 |
| Cylinder Arrangement | V-Type |
| Stroke Type | 4-Stroke |
| Class of Insulation | H-Class |
| Bore × Stroke (mm) | 135 mm × 150 mm |
| Displacement | 25 – 30 Litres |
| Cooling System | Water-cooled (Radiator / Heat Exchanger) |
| Parameter | Specification |
|---|---|
| Model | IGM12VTDG-700B5LC |
| Voltage (V) | 400 V |
| Frequency (Hz) | 50 Hz |
| Power Output (kW) | 700 kW |
| Apparent Power (kVA) | 875 kVA |
| Power Factor (Lagging) | 0.8 |
| Speed (RPM) | 1500 |
| Genset Prime Rating (kVA) | 875 kVA |
| Duty | Prime / Standby |
| Power Rating @ 100% kWe | 700 kW |
| No. of Phases | 3-Phase |
| Output Voltage (V) | 400 V |
| Current (A) | 1264 A |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Governing Class | G2 or ISO 8528 Class G2 |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM12VTDG-700B5LC |
| Rated Engine Power (kW) | 720 – 750 kW |
| No. of Cylinders | 12 |
| Cylinder Arrangement | V-type |
| Stroke Type | 4-Stroke |
| Class of Insulation | H Class |
| Bore x Stroke (mm) | 135 mm x 150 mm |
| Displacement (Litres) | 25 – 30 L |
| Cooling System | Water-cooled with radiator |
| Parameter | Specification |
|---|---|
| Model | IGM6CG-500B5HC |
| Voltage (V) | 10,500 V |
| Frequency (Hz) | 50 Hz |
| Power Output (kW) | 500 kW |
| Apparent Power (kVA) | 625 kVA |
| Power Factor (lagging) | 0.8 |
| Speed (RPM) | 1500 |
| Duty Rating | Prime / Standby |
| Power Rating @ 100% kWe | 500 kW |
| Number of Phases | 3 Phase |
| Output Voltage | 10.5 kV |
| Current (A) | 34.4 A |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Governing Class | G2 (±1% Frequency Regulation) |
| Engine Type | Specification |
|---|---|
| Brand | IGAMOGEN |
| Model | IGM6CG-500B5HC |
| Rated Engine Power (kW) | 550 kW |
| Number of Cylinders | 12 |
| Cylinder Arrangement | V-type |
| Stroke | 4-Stroke |
| Class of Insulation | H-Class |
| Bore x Stroke (mm) | 135 mm x 150 mm |
| Displacement | 24 – 30 Litres |
| Cooling System | Water-cooled |
| Parameter | Specification |
|---|---|
| Model | IGM6CG-500B5LC |
| Voltage (V) | 400 V |
| Frequency (Hz) | 50 Hz |
| Power Output (kW) | 500 kW |
| Apparent Power (kVA) | 625 kVA |
| Power Factor (lagging) | 0.8 |
| Speed (r/min) | 1500 RPM |
| No. of Phases | 3 Phase |
| Output Voltage (V) | 400 V |
| Current (A) | 902 A |
| Governing Class | G2 |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Duty Rating | Prime / Standby |
| Power Rating @ 100% kWe | 500 kW |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM6CG-500B5LC |
| Rated Engine Power | 520–550 kW |
| Number of Cylinders | 41068 |
| Cylinder Arrangement | Inline / V-type |
| Stroke Type | 4-Stroke |
| Bore x Stroke (mm) | 135 mm x 150 mm |
| Displacement (Litres) | 12–25 L |
| Cooling System | Water-cooled |
| Class of Insulation | H Class |
| Parameter | Specification |
|---|---|
| Model | IGM6CG-400B5LC |
| Genset Prime Rating (kVA) | 500 kVA |
| Duty | Prime |
| Power Rating @ 100% kWe | 400 kW |
| No. of Phases | 3 Phase |
| Output Voltage | 400 V |
| Electrical Efficiency / Thermal Efficiency | Estimated: 39% / 44% |
| Total Efficiency | 0.83 |
| Power Factor (lagging) | 0.8 |
| Current (A) | 721 A |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Governing Class | G2 (ISO 8528-5 Compliant) |
| Genset Dimensions (L × W × H) | 4107 × 1633 × 2111 mm |
| Genset Weight (Approx.) | 8890 kg |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM6CG-400B5LC |
| Rated Power (kW) | 400 kW |
| No. of Cylinders | 8 |
| Cylinder Arrangement | Inline / V-type |
| Stroke | 4-Stroke |
| Class of Insulation | Class H |
| Bore × Stroke (mm) | Estimated: 135 × 150 mm |
| Displacement (Ltr) | Approx. 16–20 L |
| Cooling System | Water-Cooled, Radiator Type |
| Fuel Consumption @ 75% Load (kg/hr) | 105–115 kg/hr |
| Fuel Consumption @ 100% Load (kg/hr) | 130–145 kg/hr |
| Oil Capacity (L) | 40–60 L |
| Coolant Capacity (L) | 50–70 L |
| Parameter | Specification |
|---|---|
| Genset Prime Rating (kVA) | 437.5 kVA |
| Duty | Prime |
| Power Rating @ 100% kWe | 350 kW |
| No. of Phases | 3 Phase |
| Output Voltage (V) | 400 V |
| Electrical Efficiency / Thermal Efficiency | 38% / 45% |
| Total Efficiency | 0.83 |
| Power Factor (lagging) | 0.8 |
| Current (A) | 631 A |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Governing Class | G2 (as per ISO 8528-5) |
| Genset Dimensions (L × W × H) | 3900 × 1850 × 2290 mm |
| Genset Weight (Approx.) | 5500 kg |
| Engine Type | Specification |
|---|---|
| Parameter | Details |
| Brand | IGAMOGEN |
| Model | IGM6TDG-350B5LC |
| Rated Power (kW) | 350 kW |
| No. of Cylinders | 6 or 8 |
| Cylinder Arrangement | Inline / V-Type |
| Stroke | 4-Stroke |
| Class of Insulation | Class H |
| Bore × Stroke (mm) | 135 × 150 mm |
| Displacement (Ltr) | 12–17 L |
| Cooling System | Water Cooled (Radiator Based) |
| Fuel Consumption @ 75% Load (kg/hr) | 90–95 kg/hr |
| Fuel Consumption @ 100% Load (kg/hr) | 115–125 kg/hr |
| Oil Capacity (L) | 30–50 L |
| Coolant Capacity (L) | 35–60 L |
| Parameter | Specification |
|---|---|
| Genset Model | IGM6TDG-300B5LC |
| Genset Prime Rating (kVA) | 375 kVA |
| Duty | Prime |
| Power Rating @ 100% kWe (in kW) | 300 kW |
| No. of Phases | 3 Phase |
| Output Voltage (V) | 400 V |
| Electrical Efficiency / Thermal Efficiency | 38% / 45% |
| Total Efficiency | 0.83 |
| Power Factor (lagging) | 0.8 |
| Current Output (A) | 541 A |
| Frequency & RPM | 50 Hz / 1500 RPM |
| Governing Class | G2 (ISO 8528-5 standard) |
| Genset Dimensions (L × W × H) | 3900 × 1850 × 2290 mm |
| Genset Weight | 5500 kg |
| Engine Type | Specification |
|---|---|
| Engine Brand | IGAMOGEN |
| Engine Model | IGM6TDG-300B5LC |
| Rated Power (KW) | 300 kW |
| No. of Cylinders | 6 |
| Cylinder Arrangement | Inline |
| Stroke Type | 4-stroke |
| Class of Insulation | Class H (Standard for alternators) |
| Bore × Stroke (mm) | 135 x 150 mm |
| Displacement (Ltr) | 10–15 L for 300 Kw |
| Cooling System | Water Cooled |
| Fuel Consumption @ 75% Load | 70–80 kg/hr |
| Fuel Consumption @ 100% Load | 95–110 kg/hr |
| Oil Capacity (L) | 25–40 L |
| Coolant Capacity (L) | 30–50 L |
| Parameter | Specification |
|---|---|
| Model | IGM6TG-250B5LC |
| Genset Prime Rating (kVA) | 312.5 kVA |
| Duty | Prime / Continuous |
| Power Rating @ 100% kWe | 250 kW |
| Apparent Power (kVA) | 312.5 kVA |
| Power Factor (Lagging) | 0.8 |
| No. of Phases | 3 Phase |
| Output Voltage | 400 V |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Governing Class | G2 |
| Electrical Efficiency | ~38% (Typical) |
| Thermal Efficiency | ~45% (Typical) |
| Total Efficiency | ~83% (Electrical + Thermal) |
| Current Output | 451 A |
| Class of Insulation | H Class |
| Engine Type | Specification |
|---|---|
| Brand | IGAMOGEN |
| Model | IGM6TG-250B5LC |
| Rated Power | 250 kW |
| No. of Cylinders | 6 |
| Cylinder Arrangement | Inline |
| Stroke Type | 4-stroke |
| Bore x Stroke (mm) | 135 x 150 mm |
| Displacement | [e.g., 9.7 L] |
| Cooling System | Water-cooled |
| Fuel Type | Biogas |
| Fuel Consumption @ 75% Load | 65-70 kg/hr |
| Fuel Consumption @ 100% Load | 85-90 kg/hr |
| Oil Capacity | 25-30 L |
| Coolant Capacity | 35-40 L |